Quad-4 Dual Hall Effect Pickup Module
Installation and Technical Data Guide
AW Flow Meters - Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Rev 07/09
Sinking Output Circuit
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog
Switch
Sourcing Output Circuit - Default from Factory
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog
Switch
• Output selection jumper off: remove shorting block from
JP1 & JP2
• User may need to add external components to interface
to displays or other instruments
• User must limit output voltage to Supply -1V
• Max current sinking capability: 50mA
• Output selection jumper on: place shorting block across
JP1 & JP2
• Signal output square wave :
V
high
= Supply -1V @ no output load
V
low
= 0.1V
• Max sourced output voltage: Supply -0.5V
• Max current sourcing capabilities: 50mA
Supply Voltage: +10 to 27 Volt DC
Supply Current: 75 mA @ 24 VDC
Duty Signal: 50% ± 15%
Minimum Signal: 0.5 Hz
Maximum Signal: 1,000 Hz
Frequency Output: Flow dependent, up to 2,000 Hz
Driving Capacity: 50 mA Max resistive load
Output Impedance: ~ 40 Ohm - analog switch and self-resetting fuse
Temperature Range: -40° F to 185° F (-40° C to 85° C)
Technical Data: